Resultados 1 - 20 de 88
Filtrar
1.
J Diabetes Sci Technol ; : 19322968241245627, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613225

RESUMO

BACKGROUND: Benefits of hybrid closed-loop (HCL) systems in a high-risk group with type 1 diabetes and impaired awareness of hypoglycemia (IAH) have not been well-explored. METHODS: Adults with Edmonton HYPO scores ≥1047 were randomized to 26-weeks HCL (MiniMed™ 670G) vs standard therapy (multiple daily injections or insulin pump) without continuous glucose monitoring (CGM) (control). Primary outcome was percentage CGM time-in-range (TIR; 70-180 mg/dL) at 23 to 26 weeks post-randomization. Major secondary endpoints included magnitude of change in counter-regulatory hormones and autonomic symptom responses to hypoglycemia at 26-weeks post-randomization. A post hoc analysis evaluated glycemia risk index (GRI) comparing HCL with control groups at 26 weeks post-randomization. RESULTS: Nine participants (median [interquartile range (IQR)] age 51 [41, 59] years; 44% male; enrolment HYPO score 1183 [1058, 1308]; Clarke score 6 [6, 6]; n = 5 [HCL]; n = 4 [control]) completed the study. Time-in-range was higher using HCL vs control (70% [68, 74%] vs 48% [44, 50%], P = .014). Time <70 mg/dL did not differ (HCL 3.8% [2.7, 3.9] vs control 6.5% [4.3, 8.6], P = .14) although hypoglycemia episode duration was shorter (30 vs 50 minutes, P < .001) with HCL. Glycemia risk index was lower with HCL vs control (38.1 [30.0, 39.2] vs 70.8 [58.5, 72.4], P = .014). Following 6 months of HCL use, greater dopamine (24.0 [12.3, 27.6] vs -18.5 [-36.5, -4.8], P = .014), and growth hormone (6.3 [4.6, 16.8] vs 0.5 [-0.8, 3.0], P = .050) responses to hypoglycemia were observed. CONCLUSIONS: Six months of HCL use in high-risk adults with severe IAH increased glucose TIR and improved GRI without increased hypoglycemia, and partially restored counter-regulatory responses. CLINICAL TRIAL REGISTRATION: ACTRN12617000520336.

2.
J Diabetes Sci Technol ; : 19322968241236771, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491800

RESUMO

BACKGROUND: Combining a continuous glucose monitor with an insulin delivery cannula (CGM-IS) could benefit clinical outcomes. We evaluated the feasibility of a single-needle insertion electrochemical investigational CGM-IS (Pacific Diabetes Technologies, Portland, Oregon) in type 1 diabetes adults. METHODS: Following 48 hours run-in using a Medtronic 780G in manual mode with a commercial insulin set, 12 participants commenced insulin delivery using the CGM-IS. A standardized test meal was eaten on the mornings of days 1 and 4. Venous samples were collected every 10 minutes one hour prior to and 15 minutes post-meal for four hours. CGM-IS glucose measurements were post-processed with a single capillary blood calibration during warm-up and benchmarked against YSI. A Dexcom G6 sensor was worn post-consent to study end. RESULTS: Mean absolute relative difference (MARD) for the CGM-IS glucose measurements was 9.2% (484 paired data points). Consensus error grid revealed 88.6% within zone A and 100% in A + B. Mean (SD) % bias was -3.5 (11.7) %. There were 35 paired YSI readings <100 mg/dL cutoff and 449 ≥100 mg/dL with 81.4% within ±15 mg/dL or ±15%, and 89.9% within ±20 mg/dL or ±20%. Two cannula occlusions required discontinuation of insulin delivery: one at 70 hours post insertion and another during the day 4 meal test. Mean (SD) Dexcom glucose measurements during run-in and between meal tests was respectively 161.3 ± 27.3 mg/dL versus 158.0 ± 25.6 mg/dL; P = .39 and corresponding mean total daily insulin delivered by the pump was 58.0 ± 25.4 Units versus 57.1 ± 28.8 Units; P = .47. CONCLUSIONS: Insulin delivery and glucose sensing with the investigational CGM-IS was feasible. Longer duration studies are needed.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38315502

RESUMO

Older adults with type 1 diabetes may face challenges driving safely. Glucose "above 5 to drive" is often recommended for insulin-treated diabetes to minimize hypoglycemia while driving. However, the effectiveness of this recommendation among older adults has not been evaluated. Older drivers with type 1 diabetes were assessed while using sensor-augmented insulin pumps during a 2-week clinical trial run-in. Twenty-three drivers (median age 69 years [IQR 65-72]; diabetes duration 37 years [20-45]) undertook 618 trips (duration 10 min [5-21]). Most trips (n = 535; 87%) were <30-min duration; nine trips (1.5%) exceeded 90 min and three trips (0.5%) exceeded 120 min. Pre-trip continuous glucose monitoring (CGM) was >5.0 mmol/L for 577 trips (93%) and none of these had CGM <3.9 mmol/L during driving (including eight trips >90 min and three trips >120 min). During 41 trips with pre-trip CGM ≤5.0 mmol/L, 11 trips had CGM <3.9 mmol/L. Seventy-one CGM alerts occurred during 60 trips (10%), of which 54/71 (76%) were unrelated to hypoglycemia. Our findings support a glucose "above-5-to-drive" recommendation to avoid CGM-detected hypoglycemia among older drivers, including for prolonged drives, and highlight the importance of active CGM low-glucose alerts to prevent hypoglycemia during driving. Driving-related CGM usability and alert functionality warrants investigation.

4.
Diabetes Care ; 47(4): 747-755, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38381515

RESUMO

OBJECTIVE: To determine feasibility and compare acceptance of an investigational Medtronic enhanced advanced hybrid closed-loop (e-AHCL) system in adults with type 1 diabetes with earlier iterations. RESEARCH DESIGN AND METHODS: This nonrandomized three-stage (12 weeks each) exploratory study compared e-AHCL (Bluetooth-enabled MiniMed 780G insulin pump with automatic data upload [780G] incorporating an updated algorithm; calibration-free all-in-one disposable sensor; 7-day infusion set) preceded by a run-in (non-Bluetooth 780G [670G V4.0 insulin pump] requiring manual data upload; Guardian Sensor 3 [GS3] requiring calibration; 3-day infusion set), stage 1 (780G; GS3; 3-day infusion set), and stage 2 (780G; calibration-free Guardian Sensor 4; 3-day infusion set). Treatment satisfaction was assessed by Diabetes Technology Questionnaire (DTQ)-current (primary outcome) and other validated treatment satisfaction tools with glucose outcomes by continuous glucose monitoring metrics. RESULTS: Twenty-one of 22 (11 women) participants (baseline HbA1c 6.7%/50 mmol/mol) completed the study. DTQ-current scores favored e-AHCL (123.1 [17.8]) versus run-in (101.6 [24.2]) and versus stage 1 (110.6 [20.8]) (both P < 0.001) but did not differ from stage 2 (119.4 [16.0]; P = 0.271). Diabetes Medication System Rating Questionnaire short-form scores for "Convenience and Efficacy" favored e-AHCL over run-in and all stages. Percent time in range 70-180 mg/dL was greater with e-AHCL versus run-in and stage 2 (+2.9% and +3.6%, respectively; both P < 0.001). Percent times of <70 mg/dL for e-AHCL were significantly lower than run-in, stage 1, and stage 2 (-0.9%, -0.6%, and -0.5%, respectively; all P < 0.01). CONCLUSIONS: e-AHCL was feasible. User satisfaction increased compared with earlier Medtronic HCL iterations without compromising glucose control.


Assuntos
Diabetes Mellitus Tipo 1 , Insulinas , Adulto , Humanos , Feminino , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Algoritmos , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico
5.
Artigo em Inglês | MEDLINE | ID: mdl-38373265

RESUMO

OBJECTIVE: We compared treatment satisfaction with a tubeless insulin pump (Omnipod DASH® Insulin Management System) to usual care (multiple daily injections [MDI] or tubed insulin pump therapy [IPT]) in adults with type 1 diabetes using self-monitoring blood glucose (SMBG). RESEARCH DESIGN AND METHODS: Adults with type 1 diabetes on MDI (n = 40) or IPT (n = 25) from four diabetes centers in Australia were randomized in a 1:1 non-blinded manner to Omnipod DASH System (Omnipod group) or continue usual care (Usual Care group) for 12 weeks, followed by a further 12-week extension where all participants used the device. The primary outcome was treatment satisfaction assessed by change in Diabetes Technology Questionnaire 'current' (ΔDTQ-current) score at 12-weeks (study-end). Secondary outcomes included ΔDTQ-current following extension and other participant-reported outcomes (PROs) measuring quality of life, burden of disease treatment, glycemic and device-related outcomes at 12-weeks (study-end) and 24-weeks (end-extension). RESULTS: Treatment satisfaction improved more in Omnipod group vs. Usual Care group (ΔDTQ-current score of 16.4 [21.2] vs. 0.0 [12.8]; p < 0.001) at study-end. Significantly greater improvements in other PROs and HbA1c were also observed. Improvements in DTQ-current and other PROs comparing study-end and end-extension were similar. While %TIR change from baseline did not differ at study-end (-2.0 [12.7] %), it was significantly greater at end-extension (5.6 [10.9] %; p = 0.016). CONCLUSIONS: Omnipod DASH System resulted in greater treatment satisfaction at 12 weeks in adults with type 1 diabetes using SMBG which was sustained after 24 weeks of device use without compromising sleep quality and fear of hypoglycemia. Improvements in glycemia were also observed.

6.
Diabetes Res Clin Pract ; 208: 111123, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38309532

RESUMO

AIMS: Understanding the lived experience of using a tubeless insulin pump and how this differs compared to usual care (tubed insulin pump therapy (IPT) vs multiple daily injections (MDI)). METHODS: Interviews were conducted after 12-weeks of using the Omnipod DASH Insulin Management System (Insulet, Acton, MA) and analysed using thematic analysis. RESULTS: Fifty-eight adults (35 female; mean age 42;SD 13 years; 35 previous MDI) were interviewed. Most (84 %) wanted to continue using the device. Experiences fit two themes: 1. Taking back control of my diabetes: many previous MDI users perceived improved glycaemic control, explained by more "nuanced" control, with some reporting positive effects during exercise and sleep. Many previous MDI and IPT users endorsed positive experiences in concealing or disclosing their diabetes to others. However, some previous MDI users reported negative psychosocial experiences due to feeling continuously "attached" to their diabetes. 2. Barriers and facilitators of device acceptability: both MDI and IPT users cited wearability, alarms and the financial cost impacted their choice to continue device use. IPT users reported positive wearability experiences. CONCLUSIONS: The tubeless pump improved diabetes management perceptions for both MDI and tubed pump users. However, participants' prior glucose management affected perceptions of its advantages and disadvantages.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Hipoglicemiantes/uso terapêutico , Austrália , Insulina/uso terapêutico , Injeções , Sistemas de Infusão de Insulina , Glicemia
7.
J Diabetes Complications ; 38(3): 108702, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38387103

RESUMO

AIMS: To relate adverse events with glucose correction rates in diabetic ketoacidosis (DKA) using variable rate intravenous insulin-infusions (VRIII). METHODS: Retrospective, observational study in adults with DKA who received insulin infusions between 2012 and 2017 at St Vincent's Hospital, Melbourne. Early correction of hyperglycaemia (<10 mmol/L) was evaluated for association with hypoglycaemia (<4.0 mmol/L), hypokalaemia (potassium <3.3 mmol/L) and clinical outcomes via regression analysis. RESULTS: The study involved 97 patients, with 93 % having type 1 diabetes. The mean age was 38 years, 47 % were women and 35 % were admitted to intensive care. Hypoglycaemia rates during 12 and 24 h of treatment were 6.2 % and 8.2 %, respectively with 58 % of patients recording their first BGL <10 mmol/L within 12 h and 88 % within 24 h. Ketone clearance time averaged at 15.6 h. Hyperglycaemia correction rates to <10 mmol/L were not different in those with/without hypoglycaemia at 12/24 h, in multivariate analysis including admission BGL. Hypokalaemia occurred in 40.2 % of patients and was associated with lower pH but not BGL correction rates. CONCLUSION: The VRIII protocol achieved early hyperglycaemia correction and ketoacidosis reversal with low hypoglycaemia risk. However, high hypokalaemia rates suggest the need for aggressive potassium replacement, especially in markedly acidotic patients.


Assuntos
Diabetes Mellitus , Cetoacidose Diabética , Hiperglicemia , Hipoglicemia , Hipopotassemia , Adulto , Feminino , Humanos , Masculino , Cetoacidose Diabética/tratamento farmacológico , Cetoacidose Diabética/epidemiologia , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipopotassemia/induzido quimicamente , Hipopotassemia/epidemiologia , Insulina/efeitos adversos , Insulina Regular Humana , Potássio , Estudos Retrospectivos
8.
Diabetes Technol Ther ; 26(S3): 84-96, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377316

RESUMO

The physical and psychological benefits of exercise are particularly pertinent to people with type 1 diabetes (T1D). The variability in subcutaneous insulin absorption and the delay in offset and onset in glucose lowering action impose limitations, given the rapidly varying insulin requirements with exercise. Simultaneously, there are challenges to glucose monitoring. Consequently, those with T1D are less likely to exercise because of concerns regarding glucose instability. While glucose control with exercise can be enhanced using automated insulin delivery (AID), all commercially available AID systems remain limited by the pharmacokinetics of subcutaneous insulin delivery. Although glycemic responses may vary with exercises of differing intensities and durations, the principles providing the foundation for guidelines include minimization of insulin on board before exercise commencement, judicious and timely carbohydrate supplementation, and when possible, a reduction in insulin delivered in anticipation of planned exercise. There is an increasing body of evidence in support of superior glucose control with AID over manual insulin dosing in people in T1D who wish to exercise. The MiniMed™ 780G AID system varies basal insulin delivery with superimposed automated correction boluses. It incorporates a temporary (elevated glucose) target of 8.3 mmol/L (150 mg/dL) and when it is functioning, the autocorrection boluses are stopped. As the device has recently become commercially available, there are limited data assessing glucose control with the MiniMed™ 780G under exercise conditions. Importantly, when exercise was planned and implemented within consensus guidelines, %time in range and %time below range targets were met. A practical approach to exercising with the device is provided with illustrative case studies. While there are limitations to spontaneity imposed on any AID device due to the pharmacokinetics associated with the subcutaneous delivery of current insulin formulations, the MiniMed™ 780G system provides people with T1D an excellent option for exercising safely if the appropriate strategies are implemented.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Glicemia , Automonitorização da Glicemia , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
9.
J Diabetes Investig ; 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38366869

RESUMO

The gold standard for measuring insulin sensitivity (IS) is the hyperinsulinemic-euglycemic clamp, a time, costly, and labor-intensive research tool. A low insulin sensitivity is associated with a complication-risk in type 1 diabetes. Various formulae using clinical data have been developed and correlated with measured IS in type 1 diabetes. We consolidated multiple formulae into an online calculator (bit.ly/estimated-GDR), enabling comparison of IS and its probability of IS <4.45 mg/kg/min (low) or >6.50 mg/kg/min (high), as measured in a validation set of clamps in 104 adults with type 1 diabetes. Insulin sensitivity calculations using different formulae varied significantly, with correlations (R2 ) ranging 0.005-0.87 with agreement in detecting low and high glucose disposal rates in the range 49-93% and 89-100%, respectively. We demonstrate that although the calculated IS varies between formulae, their interpretation remains consistent. Our free online calculator offers a user-friendly tool for individual IS calculations and also offers efficient batch processing of data for research.

10.
J Diabetes Sci Technol ; : 19322968241231307, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38372246

RESUMO

BACKGROUND: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. METHODS: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). RESULTS: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference -22.8 [-27.2, -18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms (r = -.954; P = .001), and positively with TAR >250 mg/dL (r = .901; P = .001), TBR < 54 mg/dL (r = .416; P = .001), and glycemic variability (SD [r = .916] and CV [r = .732]; P = .001 for both). CONCLUSIONS: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.

12.
Diabet Med ; 41(3): e15195, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37562414

RESUMO

AIMS: To examine the psychometric properties of the Diabetes Management Experiences Questionnaire (DME-Q). Adapted from the validated Glucose Monitoring Experiences Questionnaire, the DME-Q captures satisfaction with diabetes management irrespective of treatment modalities. METHODS: The DME-Q was completed by adults with type 1 diabetes as part of a randomized controlled trial comparing hybrid closed loop (HCL) to standard therapy. Most psychometric properties were examined with pre-randomization data (n = 149); responsiveness was examined using baseline and 26-week follow-up data (n = 120). RESULTS: Pre-randomization, participants' mean age was 44 ± 12 years, 52% were women. HbA1c was 61 ± 11 mmol/mol (7.8 ± 1.0%), diabetes duration was 24 ± 12 years and 47% used an insulin pump prior to the trial. A forced three-factor analysis revealed three expected domains, that is, 'Convenience', 'Effectiveness' and 'Intrusiveness', and a forced one-factor solution was also satisfactory. Internal consistency reliability was strong for the three subscales ( α range = 0.74-0.84) and 'Total satisfaction' ( α = 0.85). Convergent validity was demonstrated with moderate correlations between DME-Q 'Total satisfaction' and diabetes distress (PAID: rs = -0.57) and treatment satisfaction (DTSQ; rs = 0.58). Divergent validity was demonstrated with a weak correlation with prospective/retrospective memory (PRMQ: rs = -0.16 and - 0.13 respectively). Responsiveness was demonstrated, as participants randomized to HCL had higher 'Effectiveness' and 'Total satisfaction' scores than those randomized to standard therapy. CONCLUSIONS: The 22-item DME-Q is a brief, acceptable, reliable measure with satisfactory structural and construct validity, which is responsive to intervention. The DME-Q is likely to be useful for evaluation of new pharmaceutical agents and technologies in research and clinical settings.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Satisfação do Paciente , Psicometria , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estudos Prospectivos , Glicemia , Inquéritos e Questionários
13.
J Sleep Res ; : e14106, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38050705

RESUMO

Hypoglycaemia during sleep is a common and clinically important issue for people living with insulin-treated diabetes. Continuous glucose monitoring devices can help to identify nocturnal hypoglycaemia and inform treatment strategies. However, sleep is generally inferred, with diabetes researchers and physicians using a fixed-overnight period as a proxy for sleep-wake status when analysing and interpretating continuous glucose monitoring data. No study to date has validated such an approach with established sleep measures. Continuous glucose monitoring and research-grade actigraphy devices were worn and sleep diaries completed for 2 weeks by 28 older adults (mean age 67 years [SD 5]; 17 (59%) women) with type 1 diabetes. Using continuous glucose monitoring data from a total of 356 nights, fixed-overnight (using the recommended period of 00:00 hours-06:00 hours) and objectively-measured sleep periods were compared. The fixed-overnight period approach missed a median 57 min per night (interquartile range: 49-64) of sleep for each participant, including five continuous glucose monitoring-detected hypoglycaemia episodes during objectively-measured sleep. Twenty-seven participants (96%) had at least 1 night with continuous glucose monitoring time-in-range and time-above-range discrepancies both ≥ 10 percentage points, a clinically significant discrepancy. The utility of fixed-overnight time continuous glucose monitoring as a proxy for sleep-awake continuous glucose monitoring is inadequate as it consistently excludes actual sleep time, obscures glycaemic patterns, and misses sensor hypoglycaemia episodes during sleep. The use of validated measures of sleep to aid interpretation of continuous glucose monitoring data is encouraged.

14.
Pilot Feasibility Stud ; 9(1): 171, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37814352

RESUMO

BACKGROUND: Insulin pump therapy (IPT) improves glucose control in people with type 1 diabetes (T1D) compared with multiple daily injections (MDI). However, their size, the tethered insulin infusion set, intrusiveness when operating the device and the need to disconnect during showering limit their acceptance to many who may benefit. The Omnipod DASH® Insulin Management System is a small waterproof tubeless device which is wirelessly controlled by a handheld device which may be an acceptable alternative. However, there are no randomised controlled trials focusing on the impact on user perceptions of tubeless insulin pump therapy. This pilot study aims to assess study feasibility and acceptability of patch pump therapy compared with usual care in adults with T1D in Australia to inform power calculations and progression to a large-scale multi-site randomised controlled study. METHODS: A pilot multi-site parallel randomised controlled study will be conducted in sixty-four adults with T1D who are managed on MDI or IPT and self-monitoring with finger-stick blood glucose from four specialist diabetes centres in Victoria, Australia. Following carbohydrate counting education, participants will be randomised to use Omnipod DASH® System (Omnipod group) or continue usual care (usual care group) for 12 weeks, followed by a 12-week extension phase where all participants will use Omnipod DASH® System. The primary outcome measure is feasibility determined by study completion rates with a threshold of 0.80. Acceptability of the intervention (Omnipod DASH® System) will be assessed by the difference in Diabetes Technology Questionnaire 'current' (DTQ-current) score at 12 weeks post-randomisation compared to baseline. Secondary outcomes will include other measures of user acceptance, process outcomes, resource outcomes, participant-centred outcomes, healthcare professional perceptions and glycaemic outcomes. DISCUSSION: This pilot study will provide insights regarding the feasibility of the study design and the first data regarding user acceptance of insulin patch pump technology in Australian T1D adults. We anticipate that this study will provide information informing the design of a larger study evaluating the impact of patch pumps on subjective outcomes that are of significance to the person living with T1D. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ( https://anzctr.org.au/ ) ACTRN12621001195842 (8th September 2021). Please refer to Additional file 1: Appendix 1 for full details.

15.
J Diabetes Complications ; 37(10): 108597, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37659140

RESUMO

microRNAs (miRs), including miR-142, modulate gene expression and processes implicated in vascular damage and may serve as therapeutic targets and agents, including in Type 1 diabetes (T1D). The project aimed to assess whether miR-142 levels differ between people with and without T1D, and to analyse miR-142 associations with cardiovascular (CVD) risk factors. Intracellular miRs were isolated from whole blood cell pellets using TRIzol-based methodology. In a cross-sectional study in 102 adults cellular miR-142 levels were significantly higher (on unadjusted and adjusted analyses) in 69 adults with T1D relative to 33 non-diabetic subjects: mean ± SD, 3.53 ± 3.66 vs. 1.25 ± 0.78, p < 0.0002, but were not related to HbA1c levels. Further miR-142 research, including longitudinal and intervention studies and basic science are of interest. miR-142 may be valuable in clinical practice for predicting health and as a treatment target.

16.
Diabetes Res Clin Pract ; 203: 110877, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37579994

RESUMO

AIMS: Mitochondrial damage is implicated in diabetes pathogenesis and complications. Mitochondrial DNA copy number (mtDNA-cn) in human Type 1 diabetes (T1D) studies are lacking. We related mtDNA-cn in T1D and non-diabetic adults (CON) with diabetes complications and risk factors. METHODS: Cross-sectional study: 178 T1D, 132 non-diabetic controls. Associations of whole blood mtDNA-cn (qPCR) with complications, inflammation, and C-peptide. RESULTS: mtDNA-cn (median (LQ, UQ)) was lower in: T1D vs. CON (271 (189, 348) vs. 320 (264, 410); p < 0.0001); T1D with vs. without kidney disease (238 (180, 309) vs. 294 (198, 364); p = 0.02); and insulin injection vs. pump-users (251 (180, 340) vs. 322 (263, 406); p = 0.008). Significant univariate correlates of mtDNA-cn: T1D: (positive) HDL-C; (negative) fasting glucose, white cell count (WCC), sVCAM-1, sICAM-1; CON: (negative) WHR (waist-hip-ratio). Detectable C-peptide in T1D increased with lowest-highest mtDNA-cn tertiles (54%, 69%, 79%, p = 0.02). Independent determinants of mtDNA-cn: T1D: (positive) HDL-C; (negative) age, sICAM-1; AUROC 0.71; CON: WCC (negative), never smoking, (positive) female, pulse pressure; AUROC 0.74. CONCLUSIONS: mtDNA-cn is lower in T1D vs. CON, and in T1D kidney disease. In T1D, mtDNA-cn correlates inversely with age and inflammation, and positively with HDL-C, detectable C-peptide and pump use. Further clinical and basic science studies are merited.

17.
Diabetes Res Clin Pract ; 202: 110830, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37451626

RESUMO

OBJECTIVE: To conduct an Australian community-led survey of adults with type 1 diabetes (T1D), identifying priorities for, and barriers to, optimal use of advanced glucose management technologies. RESEARCH DESIGN AND METHODS: A 30-question online survey of current or past users of insulin pump therapy (IPT), real-time continuous glucose monitoring (RT-CGM), or intermittently scanned CGM (isCGM) explored perceptions regarding device design, access, education, outcomes, and support. RESULTS: Between November 2021 and January 2022, surveys were completed by 3,380 participants (age [mean ± SD] 45 ± 16 years; 62% female; 20 ± 14 years diabetes), with 55%, 82%, and 55% reporting experience with IPT, RT-CGM, and isCGM, respectively. Overall, most considered diabetes technology '(extremely) important' for maintaining target glucose levels (98%) and reducing hypoglycaemia severity and frequency (93%). For most, technology contributed positively to emotional well-being (IPT 89%; RT-CGM 91%; isCGM 87%), which was associated with device effectiveness in maintaining glucose in range, comfort, and convenience. Barriers included affordability (IPT 68%; RT-CGM 81%; isCGM 69%) and insufficient information for informed choices about device suitability (IPT 39%; RT-CGM 41%; isCGM 36%). CONCLUSIONS: Technology is perceived by adults with T1D as important for managing glycaemia and emotional well-being. Modifiable barriers to use include affordability, and information regarding device suitability.


Assuntos
Diabetes Mellitus Tipo 1 , Insulinas , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Glicemia , Automonitorização da Glicemia , Austrália/epidemiologia , Poder Psicológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico
18.
Diabetes Spectr ; 36(2): 127-136, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37193203

RESUMO

Regular exercise is essential to overall cardiovascular health and well-being in people with type 1 diabetes, but exercise can also lead to increased glycemic disturbances. Automated insulin delivery (AID) technology has been shown to modestly improve glycemic time in range (TIR) in adults with type 1 diabetes and significantly improve TIR in youth with type 1 diabetes. Available AID systems still require some user-initiated changes to the settings and, in some cases, significant pre-planning for exercise. Many exercise recommendations for type 1 diabetes were developed initially for people using multiple daily insulin injections or insulin pump therapy. This article highlights recommendations and practical strategies for using AID around exercise in type 1 diabetes.

19.
Diabetes Technol Ther ; 25(5): 356-362, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36802246

RESUMO

Objective: To explore the impact of missing data on the accuracy of continuous glucose monitoring (CGM) metrics collected for a 2-week period in a clinical trial. Research Design and Methods: Simulations were conducted to examine the effect of various patterns of missingness on the accuracy of CGM metrics as compared with a "complete" data set. The proportion of missing data, the "block size" in which the data were missing, and the missing mechanism were modified for each "scenario." The degree of agreement between simulated and "true" glycemic measures under each scenario was presented as R2. Results: Under all missing patterns, R2 declined as the proportion of missing data increased, however, as the "block size" of missing data increased, the percentage of missing data had a more pronounced effect on the agreement between measures. For a 14-day CGM data set to be considered representative for percentage time in range (%TIR), at least 70% of CGM data should be available over at least 10 days (R2 > 0.9). Skewed outcome measures, such as percentage time below range and coefficient of variation, were more affected by missing data than the less skewed measures (%TIR, percentage time above range, mean glucose). Conclusions: Both the degree and pattern of missing data impact upon the accuracy of recommended CGM-derived glycemic measures. In planning research, an understanding of patterns of missing data in the study population is required to gauge the likely effects of missing data on outcome accuracy. Trial registration number: Australian New Zealand Clinic Trials Registry ACTRN12616000753459.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Humanos , Glucose , Automonitorização da Glicemia , Benchmarking , Austrália
20.
J Diabetes Sci Technol ; 17(4): 1077-1084, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35466723

RESUMO

Exercise has many physical and psychological benefits and is recommended for people with type 1 diabetes; however, there are many barriers to exercise, including glycemic instability and fear of hypoglycemia. Closed-loop (CL) systems have shown benefit in the overall glycemic management of type 1 diabetes, including improving HbA1c levels and reducing the incidence of nocturnal hypoglycemia; however, these systems are challenged by the rapidly changing insulin needs with exercise. This commentary focuses on the principles, strengths, and challenges of CL in the management of exercise, and discusses potential approaches, including the use of additional physiological signals, to address their shortcomings in the pursuit of fully automated CL systems.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pâncreas Artificial , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Insulina Regular Humana/uso terapêutico